Sol3A Class AAA Solar Simulators 太陽(yáng)光模擬器
總部地址 北京市懷柔區樂(lè )園大街9號 郵編:101407
自駕車(chē)路線(xiàn):上京承高速,在15號出口下高速至楊雁路一直向北行駛,中高路右拐即到伊特克斯公司
乘車(chē)路線(xiàn):在東直門(mén)汽車(chē)站乘坐866路(東直門(mén)至雁棲開(kāi)發(fā)區)公交車(chē),至樂(lè )園大街北口站下車(chē)。
客戶(hù)服務(wù)熱線(xiàn):400-086-8156 傳 真:010-80703923 總 機:010-61702399 , 61702398 客戶(hù)服務(wù)郵箱: sales@etelux.com 海外業(yè)務(wù)中心聯(lián)系方式 電話(huà):0086-10-56708156 郵箱:international@etelux.com | 伊特克斯電池智能裝備 柱狀及軟包電池智能制造裝備 客戶(hù)服務(wù)熱線(xiàn):400-086-8156 傳真:010-80703923 手機:13910659652 |
分支機構聯(lián)系方式 為了給用戶(hù)提供全面、及時(shí)的售前、售后服務(wù),伊特克斯在銷(xiāo)售、服務(wù)網(wǎng)絡(luò )覆蓋全國。
伊特克斯在國內不設代理商,所有分支機構均屬于我公司直接下屬機構。辦事處詳細情況請咨詢(xún)服務(wù)熱線(xiàn) 400-086-8156
?全國聯(lián)系方式: |
||
華北一區(北京、天津、河北) |
李經(jīng)理:13918180432 |
郵箱:liminghua@etelux.com |
華北二區(北京) |
王經(jīng)理:13811584392 |
郵箱:wangbaoqiang@etelux.com |
華北三區(黑龍江、哈爾濱、長(cháng)春) |
姜經(jīng)理:13811779217 |
郵箱:changchun@etelux.com |
華北四區(北京、山西、內蒙) |
吳經(jīng)理:15699752338 |
郵箱:wudagang@etelux.com |
華中區(河南、湖南、湖北、江西) |
占經(jīng)理:13910449037 |
郵箱:wuhan@etelux.com |
華東區(上海、江蘇、山東、浙江、福建、安徽) |
郭經(jīng)理:13918771991 |
郵箱:shanghai@etelux.com |
華南區(廣東、深圳、廣西、海南) |
區經(jīng)理:18613800921 |
郵箱:guangzhou@etelux.com |
西南區(四川、云南、貴州、重慶) |
楊經(jīng)理:13811775273 |
郵箱:chongqing@etelux.com |
西北區(陜西、寧夏、甘肅、青海、新疆) |
李經(jīng)理:13910659652 |
郵箱:xian@etelux.com |
伊特克斯"365無(wú)憂(yōu)";--超值延保服務(wù) |
“365無(wú)憂(yōu)”延保服務(wù)價(jià)值 延保服務(wù)價(jià)值 全天候 全過(guò)程 更省錢(qián) 更及時(shí) 更安心 更方便 維修費用可控 專(zhuān)業(yè)維護服務(wù) |
★ 全天候: 一年365天為用戶(hù)提供服務(wù)。 |
★ 全過(guò)程: 一站式維修、保養、培訓服務(wù),建立完整的用戶(hù)檔案。 |
★ 更省錢(qián): 1)購買(mǎi)延保服務(wù)后,設備維修時(shí)您無(wú)需支付任何額外費用(耗材除外); 2)免費增值服務(wù),適時(shí)更換您平時(shí)不注意報修的零部件,消除隱患,保證設備一直處于良好使用狀態(tài); 3)更優(yōu)惠的硬件升級,以滿(mǎn)足您對設備更高的需求; 4)更優(yōu)惠購買(mǎi)耗材。 |
★ 更及時(shí): 您選擇延保服務(wù)后,公司就能在工程師那里備置常用模塊化配件,工程師可以高效及時(shí)地更換出現故障的模塊,縮短維修周期,使您的生產(chǎn)工作更順暢、更高效,為您創(chuàng )造更高的利潤。 |
★ 更安心: 設備在過(guò)了1年的免費保修期后,將不再享受全免保修服務(wù),而購買(mǎi)延保服務(wù)后,您可以繼續享受免費保修,我們會(huì )定期回訪(fǎng)設備使用情況,為您提供優(yōu)質(zhì)、完善的設備保修服務(wù),免去您的后顧之憂(yōu)。 |
★ 更方便: 您只需撥打伊特克斯統一客戶(hù)服務(wù)熱線(xiàn):400-086-8156。400呼叫中心將24小時(shí)為您服務(wù),您的一切需求我們能即刻滿(mǎn)足。 |
★ 維修費用可控: 未購買(mǎi)延保服務(wù),維修費用將根據故障設備和故障情況收取,企業(yè)對設備維修費用不可控;購買(mǎi)了延保服務(wù),對維修費用就可控了,變?yōu)轭A算制投入,可大幅減少設備維修成本增加帶來(lái)的風(fēng)險。 |
★ 專(zhuān)業(yè)維護服務(wù): 讓我們的服務(wù)團隊為您提供更多專(zhuān)業(yè)支持,攜手共創(chuàng )美好未來(lái)! |
Sol3A Class AAA Solar Simulators 太陽(yáng)光模擬器
Output beam sizes 2x2", 4x4”, 6x6” , 8x8", and 12 x 12"
Factory certified Class AAA CW systems
Calibration certificate validating Class AAA performance for all 3 standards: IEC, ASTM and JIS?
Long-lived, highly reliable instruments designed specifically for 24/7 production environments
Easy lamp replacement
Non-reflective black finish reduces stray light
Temperature sensors and interlocks ensure operator safety
?
Leveraging over 40 years of experience in light source and power supply design,?Newport’s Oriel??brand is proud to introduce the latest innovation in solar
simulators – the Oriel Sol3A? Class AAA Solar Simulator family. The product?family includes:?
Model?94123A?= 12 x 12 inch Beam Size
Model?94083A?= 8 x 8 inch Beam Size
Model?94063A?= 6 x 6 inch Beam Size
Model?94043A?= 4 x 4 inch Beam Size
Model?94023A?= 2 x 2 inch Beam Size
All Oriel Sol3A solar simulators are certified to IEC 60904-9 Edition 2 (2007), JIS?C 8912, and ASTM E927-5 standards for Spectral Match, Non-Uniformity of?
Irradiance, and Temporal Instability of Irradiance. By convention, Class AAA is?reported with the first letter representing Spectral performance, the second?
letter Uniformity of Irradiance, and the third letter Temporal Stability. The Oriel?SOL 3A solar simulators all use a single lamp design to meet not one or two, but?
all three performance criteria without compromising the 1 Sun output power,?providing true Class AAA performance. The Oriel Sol3A uses a black non-
reflective finish to minimize stray light and incorporates captive screws for all?panels requiring user access to facilitate lamp replacement, alignment, and filter?
changes. Safety interlocks prevent inadvertent exposure to UV light. The Oriel?Sol3A rugged design is backed by the Newport Corporation''s world wide?
organization.
Why Class AAA?
Photovoltaic (PV) cell research and manufacturing are evolving at an amazing rate, with new technologies like thin film processes, tandem junction and multi-junction cells, organic thin films and dye sensitized cells all requiring careful evaluation of their performance. The old designation of “Class A” solar simulators had become standard in most test laboratories and manufacturing environments, but the definition of Class A has degraded to mean a system that is capable of meeting any one (typically spectral match) of the three performance parameters called out in the test methods. In October 2007 the IEC revised the method used to evaluate the performance of a solar simulator. The new standard calls for quantifying and reporting the performance of each of three performance criteria separately. A solar simulator is now measured as class A, B, or C for Spectral Match, Non-Uniformity of Irradiance, and Temporal Instability of Irradiance. The new Sol3A solar simulators have been designed to meet Class A performance for all 3 of the test requirements, Spectral Match, Non-Uniformity of Irradiance, and Temporal Instability of Irradiance as called out by IEC 60904-9 Edition 2 (2007) edition, JIS C 8912, and ASTM E 927-05.
By ensuring measurement uniformity that allows results comparability and traceability, Class AAA systems reduce binning variability of photovoltaic cell testing as compared to so called Class A, Class B or non-classified sources. This performance consistency allows for precise comparison of performance data for researchers engaged in developing novel solar materials.
Newport Corporation puts each Oriel Sol3A? through rigorous testing for all 3 standards (IEC, STM, and JIS) to insure compliance and supplies a certificate of calibration for all three standards.
Defining Class AAA Performance Standards
Photovoltaic standards mandate that Class AAA solar simulators meet demanding requirements in three key performance areas: spectral match to the solar spectrum, spatial non-uniformity of irradiance, and temporal instability of irradiance.?
There are three standards that define solar simulator performance.
IEC 60904-9 Edition 2 (2007) Photovoltaic Devices – Part 9: Solar Simulator Performance Requirements
JIS C 8912-1998, Solar Simulators for Crystalline Solar Cells and Modules
ASTM E 927-05 (2005) Specification for Solar Simulation for Terrestrial PV Testing
Table 1 Class AAA Standards and Specifications
Organization | IEC | JIS | ASTM |
Performance Parameter | 60904-9-2007 | C 8912 | E92-05 |
Spectral Match (fraction of ideal percentage) | 0.75 - 1.25 | 0.75 - 1.25 | 0.75 - 1.25 |
Non-Uniformity of Irradiance | 2.0% | 2% | |
Temporal Instability | 0.5% STI | 2% | |
? | ? | ? |
Spectral Match
The standards define the spectral match of a solar simulator as a percentage of the integrated intensity in 6 spectral ranges (listed in Table 2). Any deviation from the specified percentages must then lie within a range that determines the class of the simulator. For Class AAA, this range is 0.75 to 1.25 times the ideal percentage.
Spectral Match
Table 2 Ideal Spectral Match Defined by IEC Standards
Spectral Range (nm) | Total Irradiance Range (%) | Ideal % |
---|---|---|
400 - 500 | 13.9 - 23.1 | 18.5 |
500 - 600 | 15.1 - 25.1 | 20.1 |
600 - 700 | 13.7 - 22.9 | 18.3 |
700 - 800 | 11.1 - 18.5 | 14.8 |
800 - 900 | 9.2 - 15.3 | 12.2 |
900 - 1100 | 12.1 - 20.1 | 16.1 |
Fig. 1 Oriel Sol3A Spectral Match with AM 1.5G
spectral correction filter meets IEC, JIS, ASTM Class A?
requirements to for spectral match.
Spatial Uniformity of Irradiance
The irradiance uniformity over the work area is the most difficult Class AAA requirement to achieve and maintain. Hot spots can lead to significant errors in measured cell efficiency and can cause inaccurate binning of cells. The Class AAA spatial non-uniformity performance standard is designed to minimize the impact of hot spots and has a very stringent requirement of ≤2%. The plot below shows the uniformity of the irradiance across a typical simulator working area. Each unit will come with a plot of irradiance non-uniformity. The working distance ranges for each simulator are listed in Table 3.
Sol3A Working Distances
Table 3 Working Distances
Model | Size | Working Distance Range (Inches) |
---|---|---|
94023A | 2 x 2 (50.8 x 50.8) | 12.0 ±0.5 |
94043A | 4 x 4 (101.6 x 101.6) | 4.0 ±0.5 |
94063A | 6 x 6 (152.4 x 152.4) | 5.0 ±0.5 |
94083A | 8 x 8 (203.2 x 203.2) | 15.0 ±0.5 |
94123A | 12x12 (304.8 x 304.8) | ? |